Minimum Property Standards for One- and Two-family Dwellings, Volume 1U.S. Department of Housing and Urban Development, 1979 |
Palavras e frases frequentes
acceptable Aluminum ANSI applicable standard ASHRAE ASTM basement bathrooms beam bedrooms Brick building BUILDING INSULATION Calcium chloride cavity walls ceiling cement chimney coat Code compliance comply concrete conform construction curtain wall doors drainage ducts dwelling entrance equipment exceed exterior walls Fiberboard fire fireplace Firestopping flashing foundation wall framing garages glass Glazing Gypsum hardboard heat heater height horizontal HUD field office inches installed in accordance insulation interior joints joists kitchen labeled least less living unit loads located lumber masonry walls Maximum MECHANICAL VENTILATION metal Minimum moisture mortar nails NFPA opening panels Particleboard percent permeance piers Pipe plate Plywood Portland Cement pressure protected reinforced resistant roof SEASONAL HOMES sheathing Sheet shingles side slab slopes SMACNA soil Specifications sq ft Steel storage Structural subfloor suitable surface Table thickness Tile underlayment vapor barrier ventilation vertical width wood Wood shingles
Passagens conhecidas
Página 15 - Safety Code for Safety Glazing Materials for Glazing Motor Vehicles Operating on Land Highways
Página 4-30 - ... shall have at least one outside window which can be opened from the inside without the use of tools to provide a clear opening of not less than...
Página 5 - • ft"2 • *F~ ' and other equivalent mathematical forms. The conversion factors given in Table 1 may, therefore, be found useful. 3.1.2 thermal conductance (C) — the time rate of heat flow through a unit area of a body, induced by a unit temperature difference between the body surfaces (C in SI units, W/m2K).
Página 6 - Value of one perm is equal to one grain of water vapor per square foot per hour per inch of mercury vapor pressure difference.
Página 57 - As a typical example, brick exposed in the face of the wall other than parapet or foundations, or brick intended for structures located in regions of the United States characterized by less severe frost action or by drier climate than is found in the northeastern quarter of the United States...
Página 15 - Where the local code, regulation or requirement permits lower standards than required herein, these Minimum Property Standards shall apply. In the event the local code, regulation or requirement precludes compliance with these standards, the property may be ineligible unless the stated objectives set forth herein are fully attained by the alternate means proposed.
Página 5 - Exit is that portion of a means of egress which is separated from all other spaces of the building or structure by construction or equipment as required in this subpart to provide a protected way of travel to the exit discharge.
Página 60 - For use as architectural veneer and facing units in exterior walls and for use where high strength and resistance to moisture penetration and severe frost action are desired.
Página 6-15 - Framing members , 2 in. airspace. Airspace shall be firestopped at floor level with extension of ceiling finish, strips of asbestos board or other non-combustible material.
Página 5 - The materials or masonry units used to form a cap or finish on top of a wall, column, chimney, or pilaster to protect the masonry below from penetration of water.